Skip to main content
All vulnerabilities
CVE-2025-41450 CVSS 8.2

Danfoss AK-SM 800A Series Improper Authentication Vulnerability

Danfoss — AK-SM 800A Series

Published to NVD
8 May 2025
Disclosure to KEV listing
566 days
EPSS (30-day exploitation probability)
0.5% · 37th percentile · 25 November 2026
Added to KEV catalog
25 November 2026
Federal remediation due date
9 December 2026
Weakness classification (CWE)
CWE-305

Is CVE-2025-41450 actively exploited?

Yes. CISA added CVE-2025-41450 to its Known Exploited Vulnerabilities catalog on 25 November 2026, which means there is evidence it has been exploited in the wild. FIRST's EPSS model estimates a 0.5% probability of exploitation activity in the next 30 days, placing it in the 37th percentile of all scored CVEs.

How severe is CVE-2025-41450?

CVE-2025-41450 has a CVSS base score of 8.2 out of 10, rated High. Its CVSS vector is CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:H. The score measures technical severity; active exploitation, shown by the KEV listing, is the stronger reason to act quickly.

Which versions are affected by CVE-2025-41450?

NVD lists these affected versions for CVE-2025-41450: Danfoss Ak-Sm 800a Firmware: up to (not including) 4.2.

How do I fix CVE-2025-41450?

CISA's required action for CVE-2025-41450 is: Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines. The vendor advisory and patch links on this page point to the vendor's own fix guidance. US federal agencies must remediate it by 9 December 2026; treat that as an outside deadline, not a target.

Affected versions (NVD)

  • Danfoss Ak-Sm 800a Firmware: up to (not including) 4.2

Version ranges as published in NVD's CPE configurations. Confirm against the vendor advisory before relying on them.

AI Breakdown

What it is

Danfoss AK-SM 800A Series devices running versions prior to 4.2 contain an improper authentication vulnerability. An attacker can exploit this weakness to generate web reports that expose sensitive information, such as internal IP addresses, usernames, and store names. This enables unauthorized individuals to gather valuable network and operational intelligence without valid credentials.

Why it matters

This flaw carries a CVSS base score of 8.2 and has been cataloged by CISA due to evidence of active exploitation. Although ransomware campaign use is currently unknown, exposing internal IP addresses and account names gives attackers the exact blueprint needed for targeted follow-on attacks. Leaving these devices unaddressed presents a significant reconnaissance risk to your organization.

Recommended action

Apply vendor mitigations and upgrade all Danfoss AK-SM 8xxA Series devices to version 4.2 or later in accordance with vendor instructions and CISA BOD 26-04 guidance. Evaluate the internet exposure of all deployed assets, conduct forensic triage as needed, and discontinue use of the product if mitigations cannot be applied. Ensure these actions are prioritized to meet necessary security standards well before the December 9, 2026 federal deadline.

AI-generated from CISA and NVD data — treat as a starting point, not a substitute for your own risk assessment.

CISA Description

Danfoss AK-SM 800A Series contains an improper authentication vulnerability that could allow an attacker to generate a web report exposing sensitive information, including internal IP addresses, usernames, and store names.

Required action

Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

Notes

https://www.danfoss.com/en/service-and-support/coordinated-vulnerability-disclosure/danfoss-security-advisories/dsa-2025-03-01 ; BOD 26-04: https://www.cisa.gov/news-events/directives/bod-26-04-prioritizing-security-updates-based-risk ; Forensics Triage Requirements: https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk ; https://nvd.nist.gov/vuln/detail/CVE-2025-41450

NVD Technical Description

Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2

Confirm Your Exposure

Is this vulnerability present in your environment?

CRS delivers independent VAPT assessments that identify exactly which known-exploited vulnerabilities exist in your network, applications, and infrastructure.

Explore VAPT Services