Danfoss AK-SM 800A Series Path Traversal Vulnerability
Danfoss — AK-SM 800A Series
- Published to NVD
- 21 August 2023
- Disclosure to KEV listing
- 1191 days
- EPSS (30-day exploitation probability)
- 1.1% · 64.5th percentile · 25 November 2026
- Added to KEV catalog
- 25 November 2026
- Federal remediation due date
- 28 November 2026
- Weakness classification (CWE)
- CWE-22
Is CVE-2023-25914 actively exploited?
Yes. CISA added CVE-2023-25914 to its Known Exploited Vulnerabilities catalog on 25 November 2026, which means there is evidence it has been exploited in the wild. FIRST's EPSS model estimates a 1.1% probability of exploitation activity in the next 30 days, placing it in the 64.5th percentile of all scored CVEs.
How severe is CVE-2023-25914?
CVE-2023-25914 has a CVSS base score of 8.8 out of 10, rated High. Its CVSS vector is CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. The score measures technical severity; active exploitation, shown by the KEV listing, is the stronger reason to act quickly.
Which versions are affected by CVE-2023-25914?
NVD lists these affected versions for CVE-2023-25914: Danfoss Ak-Sm 800a Firmware: up to and including 3.3.
How do I fix CVE-2023-25914?
CISA's required action for CVE-2023-25914 is: Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines. US federal agencies must remediate it by 28 November 2026; treat that as an outside deadline, not a target.
Affected versions (NVD)
- Danfoss Ak-Sm 800a Firmware: up to and including 3.3
Version ranges as published in NVD's CPE configurations. Confirm against the vendor advisory before relying on them.
AI Breakdown
What it is
A path traversal vulnerability exists in the Danfoss AK-SM 800A Series devices through their XML interface. Authenticated attackers can exploit this flaw to retrieve and read restricted system files directly from the underlying server. Access to these sensitive files can expose critical information that could lead to a full system compromise.
Why it matters
This vulnerability carries a high CVSS score of 8.8 and can allow an attacker to gain complete control over the affected system. While ransomware campaign use is currently unknown, CISA has confirmed active exploitation in the wild by adding it to their Known Exploited Vulnerabilities catalog. Organizations running these devices face immediate operational risk if systems are exposed and left unmitigated.
Recommended action
Apply vendor-provided mitigations immediately in accordance with vendor instructions and CISA BOD 26-04 guidance. Evaluate the internet exposure of all affected assets and conduct forensics triage if suspicious activity is detected. If vendor mitigations are unavailable, isolate or discontinue use of the product to prevent unauthorized access.
AI-generated from CISA and NVD data — treat as a starting point, not a substitute for your own risk assessment.
CISA Description
Danfoss AK-SM 800A Series contains a path traversal vulnerability that could allow an attacker to access and read underlying server system files via the XML interface.
Required action
Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
Notes
https://www.danfoss.com/en/service-and-support/coordinated-vulnerability-disclosure/danfoss-security-advisories/dsa-2023-08-01 ; BOD 26-04: https://www.cisa.gov/news-events/directives/bod-26-04-prioritizing-security-updates-based-risk ; Forensics Triage Requirements: https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk ; https://nvd.nist.gov/vuln/detail/CVE-2023-25914
NVD Technical Description
Due to improper restriction, authenticated attackers could retrieve and read system files of the underlying server through the XML interface. The information that can be read can lead to a full system compromise.
More Danfoss Vulnerabilities
Is this vulnerability present in your environment?
CRS delivers independent VAPT assessments that identify exactly which known-exploited vulnerabilities exist in your network, applications, and infrastructure.